CW
Tunable
NIR
Ultra-Narrow Linewidth, CW TI:
SolsTiS-PI
Ultra-Narrow Linewidth, CW TI:
Sapphire Laser with Integrated Green Pump Laser
An evolution based on our heritage in industrial semiconductor applications, SolsTiS PI combines our award-winning SolsTiS titanium sapphire laser with our Equinox green pump laser into a single, integrated platform offering unprecedented levels of stability, compactness and ease of use while retaining all the benefits of the continuous-wave, ultra-narrow linewidth and broadly tunable architecture that SolsTiS is known for.
Features
Broad, continuous tuning range from 700-1000 nm using a single optics set
Ultra-narrow linewidths of < 100 kHz absolute linewidth
Output power levels over 5 W with high powers of >2.5 W in SHG
Ultra stable output with relative intensity noise 0.075 % RMS and exceptional stability on longer timescales
Beam pick off and fiber launch modules available
Integrated extension modules available to extend the tuning range from 210 nm to 4000 nm
Most compact laser in its class
Applications
Atom/Ion Trapping and Cooling
High-Resolution Spectroscopy
Squeezed Light
Quantum Optics
2D Materials
Colour Centres
Quantum Dots
Microresonators
Specifications
SolsTiS PI | |
---|---|
Power | > 5.0 W |
Tuning Range | 700 -1000 nm |
Linewidth | < 100 kHz |
Scan Range | > 25 GHz, measured at ~780 nm, TeraScan option available |
Amplitude Noise | < 0.075% RMS including pump noise, added in quadrature (10 Hz - 10 MHz) |
Spatial Mode | TEM00 (M2 < 1.1) |
Beam Radius | < 0.4 mm, 1/e2 intensity (nominal, at output port) |
Beam Divergence | < 1.5 mrad, far field, half angle |
Polarisation | Horizontal (pump and output beam) |
Equinox | |
Wavelength | 532 nm |
Linewidth | < 1 MHz |
Power Stability | +/- 0.5% |
Amplitude Noise | < 0.05 % RMS |
SolsTiS PI Dimensions (L x W x H) | 718.6 x 246.0 x 124.7 mm 28.29 x 9.69 x 4.91 inches |
---|---|
Ice Bloc Controller Dimensions (L x W x H) | SolsTiS: 340 mm x Half Rack x 2U Equinox: 382 x 354 x 106 mm |
Power Consumption | < 600 W total |
Electrical Requirements | 100 - 240 V, 50/ 60 Hz single phase |
Cooling | Supplied closed-loop water chiller |
Environmental Requirements | Operating temperature range: 16-30°C Maximum relative humidity: 80% non-condensing, up to 30°C |